FE-AA Auto Dose series · Electromagnetic

Auto Dose
metering pumps.

4–20 mA Signal-Responsive Dosing Pump with Low-Level Controller

The FE-AA Auto Dose series is built for set-once, steady chemical feed. Set the stroke length and speed, and the solenoid drive delivers the same dose stroke after stroke, with ±1% steady-state accuracy and a fraction of the energy of a motor-driven pump.

1.0–20.0LPH flow range
12.0kg/cm² max. pressure
±1%Steady-state accuracy
Focus FE-AA series auto dosing pump
01

Solenoid drive, no motor or gearbox

02

Flow set by stroke length and speed

03

Turn-down ratio 10:1

04

PP, PVC, PTFE or SS-316 pump heads

05

Single phase 220 V AC, 50 W

What Auto Dose means

Set it once.
Dose it right, every stroke.

Auto Dose is the name of our FE-AA series of electromagnetic metering pumps. It describes what the pump is built to do: hold a set dose automatically, hour after hour, without constant attention from the operator.

01 · Set once

Two simple controls

Output is set by stroke length and stroke speed, with a 10 : 1 turn-down ratio. Once set, the pump holds that dose on its own.

02 · Steady

Accurate and repeatable

±1% steady-state accuracy, ±3% linearity and ±3% repeatability, so the plant receives the same dose stroke after stroke.

03 · Economical

Low running cost

A 50 W solenoid drive with no motor or gearbox means lower power use, fewer wearing parts and simple maintenance.

01Model specifications

100 SPM range.

ModelMin. flow
(cc/hr)
Max. flow
(LPH)
Max. pressure
(kg/cm²)
Hydro test
(kg/cm²)
DiaphragmStrokeDriveVol. eff.Tubing (mm)Data sheet
FE-AA-101101.012.018.042 mm (No. 1)1.0 mmType 1> 70%6 × 4View
FE-AA-102202.010.015.042 mm (No. 1)1.5 mmType 1> 70%6 × 4View
FE-AA-103404.06.09.057 mm (No. 2)2.0 mmType 1> 90%9.5 × 6.35View
FE-AA-103-M1505.05.07.557 mm (No. 2)2.0 mmType 2> 90%9.5 × 6.35View
FE-AA-104606.04.06.053 mm (No. 3)2.0 mmType 2> 90%9.5 × 6.35View
FE-AA-10512010.0 / 12.03.0 / 2.04.561 mm (No. 4)1.75 mmType 2> 90%9.5 × 6.35View

FE-AA-105 is rated 10.0 LPH at 3.0 kg/cm² and 12.0 LPH at 2.0 kg/cm². Drive unit Type 1 / Type 2 refers to the solenoid drive size. End connection ½″ NPT male.

02Model specifications

180 SPM range.

ModelMax. flow
(LPH)
Max. pressure
(kg/cm²)
Hydro test
(kg/cm²)
DiaphragmStrokeSPMEnd connectionData sheet
FE-AA-686.08.012.056 mm1.5 mm180Hose, 3/8″ × 1/4″View
FE-AA-12615.0 / 10.04.0 / 5.07.053 mm1.8 mm180Hose, 3/8″ × 1/4″View
FE-AA-17317.03.04.553 mm1.8 mm180Hose, 3/8″ × 1/4″View
FE-AA-20220.02.03.053 mm1.8 mm180Hose, 3/8″ × 1/4″View

FE-AA-126 is rated 15.0 LPH at 4.0 kg/cm² and 10.0 LPH at 5.0 kg/cm². Supplied with foot valve, injection valve and LDPE hose.

03General specifications

Applies to
every model.

Make
Focus
Type
Electromagnetic, diaphragm
Stroke & speed adjustment
Manual
Flow control
Stroke length and speed controls
Capacity variation by stroke length
0 to 100% (adjust only while the pump is running)
Turn-down ratio
10:1
Steady-state accuracy
± 1%
Linearity
± 3%
Repeatability
± 3%
Noise
< 80 dB
Vibration
< 40 microns
Optional accessories
Low-level indicator with magnetic float switch
Weight
3.5 kg with PP head (without packing)

04Materials of construction

Four pump-head
options.

ComponentPP headPVC headPTFE headSS-316 head
HeadPPPVCPTFESS-316
HousingGFPPGFPPGFPPGFPP
DiaphragmTeflon-faced HypalonTeflon-faced HypalonTeflon-faced HypalonTeflon-faced Hypalon
BallCeramicCeramicCeramicCeramic
Ball sealPTFE / VitonPTFE / VitonPTFE / VitonPTFE / Viton
Suction valve seatPVCPVCPVCSS-316
Discharge valve housingPVCPVCPVCSS-316
Foot valvePVCPVCPTFESS-316
Injection valve (anti-siphon)PVCPVCPTFESS-316

Power supply

SupplySingle phase
Rating50 W
Voltage220 V AC

05Installation & dimensions

Drawings.

All dimensions in millimetres.

Installation · negative suction technical drawing
Installation · negative suction
Installation · positive suction technical drawing
Installation · positive suction
Front view technical drawing
Front view
Side view technical drawing
Side view
Foundation technical drawing
Foundation

06Data sheets

Download by model.

Each PDF covers one model: ratings, general specifications, materials, power supply and drawings.

FE-AA Auto Dose · 100 SPMPDF

FE-AA-101

Max. flow
1.0 LPH
Max. pressure
12.0 kg/cm²
FE-AA Auto Dose · 100 SPMPDF

FE-AA-102

Max. flow
2.0 LPH
Max. pressure
10.0 kg/cm²
FE-AA Auto Dose · 100 SPMPDF

FE-AA-103

Max. flow
4.0 LPH
Max. pressure
6.0 kg/cm²
FE-AA Auto Dose · 100 SPMPDF

FE-AA-103-M1

Max. flow
5.0 LPH
Max. pressure
5.0 kg/cm²
FE-AA Auto Dose · 100 SPMPDF

FE-AA-104

Max. flow
6.0 LPH
Max. pressure
4.0 kg/cm²
FE-AA Auto Dose · 100 SPMPDF

FE-AA-105

Max. flow
10.0 / 12.0 LPH
Max. pressure
3.0 / 2.0 kg/cm²
FE-AA Auto Dose · 180 SPMPDF

FE-AA-68

Max. flow
6.0 LPH
Max. pressure
8.0 kg/cm²
FE-AA Auto Dose · 180 SPMPDF

FE-AA-126

Max. flow
15.0 / 10.0 LPH
Max. pressure
4.0 / 5.0 kg/cm²
FE-AA Auto Dose · 180 SPMPDF

FE-AA-173

Max. flow
17.0 LPH
Max. pressure
3.0 kg/cm²
FE-AA Auto Dose · 180 SPMPDF

FE-AA-202

Max. flow
20.0 LPH
Max. pressure
2.0 kg/cm²

Complete series document

FE-AA Auto Dose series · all 10 models · 3 pages

Download series data sheet

Not sure which model fits?

Tell us your chemical, flow and pressure. We will size the pump.

Request a quote